d0828
Nauja prekė
Šis modulis priklausomai nuo įeinančio PWM signalo skverbties (duty cycle), keičia įtampą išėjime. Priklausomai nuo trumpiklio padėties, galimos skirtingos PWM įėjimo įtampos: 4,5-10V arba 12-24V.
Prekių kiekis mūsų sandėlyje: 14  
Dėmesio: Paskutinės prekės!
Pasiekiama:
Suderinama su Arduino™ ir *duino | Taip |
Kanalų skaičius | 1 |
Optinis atskyrimas | Taip |
Maitinimo įtampa | 12-30V |
Dažnis | 1-3 kHz |
Kontaktų kiekis | 6 |
Matmenys | 33 x 33 x 14 mm |
Pagrindinės funkcijos grandynas | LM358 |
Išėjimo įtampa | 0-10V |
Easy to operate, can be adjusted using the potentiometer;
The input level range of the PWM signal is selected by the jumper:
A) The PWM peak voltage at 4.5V-10V level (jumper inserted at 5V). This level signal is suitable for use with conventional industrial control cards (such as MACH3 board), CUP 5V interfaces;
B) The PWM peak voltage at 12V-24V level (jumper inserted at 24V); The class level signal is mainly aimed to be used with conventional PLC interfaces.
C) Conversion range: 0%-100%PWM converted to 0-10V voltage;
1 module operating voltage: 12V-30V DC (power requirements: greater than 100MA)
2.PWM signal receiving frequency range: 1KHZ-3KHZ
3.PWM signal input level range: 0-100%
4.allowable error: 5%
VCC: working power supply 12V-30V
GND: working power supply.
PWM: input PWM signal positive end.
GND: input signal.
VOUT: output voltage 0-10V.
GND: output voltage
When the signal input port is not connected, the output port gives 10V. The first time when we power on this module, we better calibrate it: find a 50% duty ratio signal, connect to DIN-, DIN+, the amplitude matches corresponding jumper. When frequency is at 1kHz ~ 3kHz, use a multi-meter to test AO, GND. The meter should be showing around 5V. We adjust the potentiometer on the converter module to make multi-meter shows 5V sharp. After this is done, we have calibrated and matched pulse signal with this converter module. The module has a definition of 0.1V. Output current 10mA. If duty ratio is in opposite to voltage, we can select or un-select PWM output pin STEP LOW / ACTIVE in MACH3 software.
When the frequency changes, the input/output relationship may be offset: need to re calibrate.
The output voltage can be adjusted by adjusting the duty cycle.
Control accuracy can be controlled by adjusting the potentiometer.