Funkcionalus įtaisas, kurį naudodami galėsite reguliuoti aplinkos temperatūrą ir drėgnumą. Mygtukais galima nustatyti įjungimo ir išjungimo temperatūras bei drėgnumo parametrus, jutiklio korekcijas, Relinis išėjimas gali valdyti iki 10A 250V apkrovas (atskirai šildymo/vėsinimo ir drėkinimo/sausinimo).

Smulkiau

Prekių kiekis mūsų sandėlyje: 3  

Dėmesio: Paskutinės prekės!

31,54€ su PVM


26,07€ be PVM

Charakteristikos

Maksimali valdoma srovė10A
Maksimali valdoma įtampa250V
Būsenos indikacijaTaip
Maitinimo įtampa6-30 V DC
Matmenys79 x 43 x 35 mm
Komunikacijų sąsajosNuosekli sąsaja
Naudojami mikrovaldiklio prievadai2vnt. UART (TX, RX)
Matavimo ribos-20 - 60 lpsn. C / 0-100%RH

Apie prekę

Features:
Function of temperature are as follows:
1.The automatic identification of work mode:
The system automatically according to the start/stop temperature, identify work mode;
Start temperature > stop temperature, cooling mode 'C'.
Start temperature < stop temperature, heating mode 'H'.
2.Cooling mode:
When the temperature ≥ Start temperature, relay conduction, red led on, refrigeration equipment begin to work;
When the temperature ≤ Stop temperature, relay disconnect, red led off, refrigeration equipment stop to work;
3.Heating mode:
When the temperature ≤ Start temperature, relay conduction, red led on, heating equipment begin to work;
When the temperature ≥ Stop temperature, relay disconnect, red led off, heating equipment stop to work;
4.Temperature correction function OFE (-10.0 ~ 10°):
The system is working for a long time and may be biased, through this function correction, the actual temperature = measuring temperature + calibration value;

How to set the start/stop temperature:
1. In the running interface, Long Press TM+ key more than 3 seconds, into the start temperature settings interface, can be modified by TM+ TM- key, to be modified, waiting for 6s automatic exit and save;
2. In the running interface, Long Press TM- key more than 3 seconds, into the stop temperature settings interface, can be modified by TM+ TM- key, to be modified after the parameters, waiting for 6s automatic exit and save;

The humidity function is as follows:
1.The automatic identification of work mode:
The system automatically according to the start/stop humidity, identify work mode;
Start humidity> stop humidity, dehumidification mode 'D'.
Start humidity< stop humidity, humidification mode 'E'.
2.Dehumidification mode:
When the humidity≥ Start humidity, relay conduction, green led on, dehumidification equipment begin to work;
When the humidity≤ Stop humidity, relay disconnect, green led off, dehumidification equipment stop to work;
3.Humidification mode:
When the humidity≤ Start humidity, relay conduction, green led on, humidification equipment begin to work;
When the humidity≥ Stop humidity, relay disconnect, green led off, humidification equipment stop to work;
4.Humidification correction function RH (-10.0 ~ 10%):
The system is working for a long time and may be biased, through this function correction, the actual humidity = measuring humidity + calibration value;

How to set the start/stop humidity:
1. In the running interface, Long Press ' RH+ ' key more than 3 seconds, into the start humidity settings interface, can be modified by RH + RH - key, to be modified, waiting for 6s automatic exit and save;
2. In the running interface, Long Press ' RH-' key more than 3 seconds, into the stop humidity settings interface, can be modified by RH+ RH- key, to be modified after the parameters, waiting for 6s automatic exit and save;

Atsiliepimai

Šiuo metu klientų atsiliepimų nėra.

Parašyti atsiliepimą

XY-WTH1 Temperatūros ir oro drėgnumo palaikymo termostatas (g.b. valdomas ir per UART)

XY-WTH1 Temperatūros ir oro drėgnumo palaikymo termostatas (g.b. valdomas ir per UART)

Funkcionalus įtaisas, kurį naudodami galėsite reguliuoti aplinkos temperatūrą ir drėgnumą. Mygtukais galima nustatyti įjungimo ir išjungimo temperatūras bei drėgnumo parametrus, jutiklio korekcijas, Relinis išėjimas gali valdyti iki 10A 250V apkrovas (atskirai šildymo/vėsinimo ir drėkinimo/sausinimo).

Priedai

15 kitos prekės toje pačioje kategorijoje:

Atsisiųsti